Winxcom Program For Calculating X-ray Attenuation Coefficients
摘要:
The theoretical values of mass attenuation coefficients have been calculated using winXcom computer program 11. Also, Figure 1 shows that, mass attenuation coefficients increase linearly with the weight fraction of PbO and decrease by increasing gamma-ray energy. In all experimental results, the estimated experimental uncertainties are about. ADS Classic is now deprecated. It will be completely retired in October 2019. Please redirect your searches to the new ADS modern form or the classic form.More info can be found on our blog. In 2011, El-Khayatt reported a new program, which called NXcom program, to calculate both fast neutrons effective removal cross-sections and c-rays (or X-ray) attenuation coefficients for any.
The total mass attenuation coefficient (μ/ρ, cm2 g-1) of gamma-ray for building materials containing with Lead Carbonate (PbCO3) have been studied. The raw building material have cement, sand and stone in the ratio 1 : 2 : 4. The raw material was mixed with 30% of PbCO3 to be used as the sample material. The mass attenuation coefficient of the raw material has been calculated by theoretical approach using WinXCom program for the photon energy band from 1 keV to 100 GeV. The composition of sample material was analyzed by energy dispersive X-ray fluorescence spectrometer (EDXRF). The variations of mass attenuation coefficient are shown graphically and compared with that of standard shielding concretes. It was found that the sample building material has higher value of mass attenuation coefficient than standard shielding concretes at energy zone above 2–7 keV, 90–800 keV and 5 MeV–100 GeV.
Witthaya Mekhum, Narong Sangwaranatee, Pichet Limsuwan, HongJoo Kim, Mitra Djamal and Jakrapong Kaewkhao
N. Chanthima et al., 'The Photon Attenuation Coefficients of Building Materials Containing with Lead Carbonate (PbCO3)', Advanced Materials Research, Vol. 979, pp. 395-400, 2014
[1] M.E. Medhat, Gamma-ray attenuation coefficients of some building materials available in Egypt, Ann. Nucl. Energy. 36 (2009) 849–852.
DOI: https://doi.org/10.1016/j.anucene.2009.02.006
[2] I. Akkurt, S. Kilincarslan, C. Basyigit, The photon attenuation coefficients of barite, marble and limra. Ann. Nucl. Energy. 31 (2004) 577–582.
DOI: https://doi.org/10.1016/j.anucene.2003.07.002
Winxcom Program For Calculating X-ray Attenuation Coefficients In Science
[3] M.I. Awadallah, M.M. Imran, Experimental investigation of c-ray attenuation in Jordanian building materials using HPGe-spectrometer. J. Environ. Radioactivity. 94 (2007) 129–136.
DOI: https://doi.org/10.1016/j.jenvrad.2006.12.015
[4] I.C.P. Salinas, C.C. Conti, R.T. Lopes, Effective density and mass attenuation coefficient for building material in Brazil. Appl. Radiat. Isot. 64 (2006) 13–18.
DOI: https://doi.org/10.1016/j.apradiso.2005.07.003
[5] C. Singh, T. Singh, A. Kumar, G.S. Mudahar, Energy and chemical composition dependence of mass attenuation coefficients of building materials. Ann. Nucl. Energy. 31 (2004) 1199–1205.
DOI: https://doi.org/10.1016/j.anucene.2004.02.002
[6] I. Türkmen, Y. Özdemir, M. Kurudirek, F. Demir, Ö. Simsek, R. Demirboğa, Calculation of radiation attenuation coefficients in Portland cements mixed with silica fume, blast furnace slag and natural zeolite. Ann. Nucl. Energy. 35 (2008).
DOI: https://doi.org/10.1016/j.anucene.2008.03.012
[7] J.H. Hubbell, S.M. Seltzer, 1995. Tables of X-ray mass attenuation coefficients and mass energy absorption coefficients 1 keV to 20MeV for elements Z = 1–92 and 48 additional substances of dosimetric interest, NISTIR 5632.
DOI: https://doi.org/10.6028/nist.ir.5632
[8] Berger, M.J., Hubbell, J.H., 1987/1999. XCOM: photon cross sections database, Web Version 1. 2, available at http: / physics. nist. gov/xcom. National Institute of Standards and Technology, Gaithersburg, MD 20899, USA. (Originally published as NBSIR 87-3597 'XCOM: Photon Cross Sections on a Personal Computer', ).
DOI: https://doi.org/10.6028/nbs.ir.87-3597
[9] L. Gerward, N. Guilbert, K.B. Jensen, H. Levring, X-ray absorption in matter. Reengineering XCOM. Radiat. Phys. Chem. 60 (2001) 23–24.
DOI: https://doi.org/10.1016/s0969-806x(00)00324-8
[10] L. Gerward, N. Guilbert, K.B. Jensen, H. Levring, WinXCom–a program for calculating X-ray attenuation coefficients. Radiat. Phys. Chem. 71 (2004) 653–654.
DOI: https://doi.org/10.1016/j.radphyschem.2004.04.040
[11] I.I. Bashter, Calculation of radiation attenuation coefficients for shielding concretes. Ann. Nucl. Energy. 24 (1997) 1389–1401.
DOI: https://doi.org/10.1016/s0306-4549(97)00003-0
[12] D.F. Jackson, D.J. Hawkes, X-ray attenuation coefficients of elements and mixtures, Phys. Rep. 70 (1981) 169–233.